Decarbonizing road transport is an urgent priority, especially for heavy goods vehicles that are crucial to the economy yet challenging to electrify. Hydrogen mobility offers a powerful alternative, delivering zero-emission journeys and supporting the transition to cleaner freight and logistics across Europe.
The European RHeaDHy project is driving innovation by enabling ultra-fast hydrogen refueling for heavy-duty vehicles. TESCOM is at the heart of this effort, providing advanced pressure regulators and shut-off valves engineered for the demanding operational environments of hydrogen stations.
TESCOM shut-off valves are designed for hydrogen applications with a maximum pressure rating of up to 15,000 psig (1034 bar). They feature reliable, leak-tight shut-off, and compact construction ideal for high-pressure hydrogen refueling stations, ensuring safety and durability.

Shut Off Valve


| Parameter | Value |
| Dimensions | D 138 mm x 264 mm |
| Weight | 22 kg |
| Design pressure | Max. inlet 1035 bar
Max. outlet 1035 bar |
| H2 maximum flow allowed | 300 g/s |
| Norms and standards | PED 2014/68/EU
ATEX 2014/34/EU |
| Pressure drop (simulated) | <10 bar at 232 g/s inlet conditions 292 bar, 20°C |